Categories

Course in Servicing the SIEMENS Aera, Skyra and MRI Family


Summary

The Servicing the SIEMENS Aera, Skyra and MRI Family course, offered by the British Academy for Training and Development, focuses on the maintenance, troubleshooting, and servicing of SIEMENS Aera, Skyra, and other MRI family systems. These advanced MRI machines are widely used for high-resolution imaging and are critical in clinical diagnostics. Ensuring these machines are properly serviced is key to maintaining their optimal performance, minimizing downtime, and ensuring patient safety.

This course will cover the core components and features of SIEMENS MRI systems, including preventive maintenance, repair procedures, calibration, troubleshooting, and safety protocols. Participants will gain the necessary skills to handle both routine and advanced issues related to these systems.

Objectives and target group

Who Should Attend?

  • MRI technicians and technologists working with SIEMENS Aera, Skyra, and MRI systems.
  • Biomedical engineers and service technicians responsible for the repair and maintenance of SIEMENS MRI machines.
  • Healthcare professionals looking to expand their knowledge in MRI system servicing and diagnostics.
  • Individuals who want to specialize in MRI system maintenance and troubleshooting.

Knowledge and Benefits:

After completing the program, participants will be able to master the following:

  • Understand the core components and operational principles of SIEMENS Aera, Skyra, and other MRI systems.
  • Perform routine maintenance and troubleshooting for SIEMENS MRI systems.
  • Conduct calibration and preventive maintenance to extend the operational life of MRI machines.
  • Identify and resolve technical issues related to magnet, gradient, RF coils, and other MRI components.
  • Apply safety standards and regulatory protocols when working with MRI systems.

Course Content

  • Overview of SIEMENS MRI Systems
    • Introduction to the SIEMENS Aera, Skyra, and MRI family systems
    • Key features and configurations of the MRI systems
    • Role of SIEMENS MRI systems in medical diagnostics
  • Basic Principles of MRI Technology
    • The physics behind MRI and how images are generated
    • Understanding magnetic fields, RF pulses, and gradient systems
    • Safety considerations when working with MRI systems
  • Magnetic System (Superconducting Magnets)
    • Understanding superconducting magnets and their role in MRI
    • Maintenance of superconducting magnets in SIEMENS systems
    • Troubleshooting common magnet issues
  • Gradient Coil System
    • The importance of gradient coils in image quality
    • Maintenance and calibration of gradient coils
    • Identifying and addressing gradient-related faults
  • Architecture of Aera and Skyra MRI Systems
    • Detailed breakdown of the components in Aera and Skyra systems
    • Comparing the Aera, Skyra, and other MRI system configurations
    • Troubleshooting common issues in Aera and Skyra MRI systems
  • Maintenance Procedures for Aera and Skyra
    • Preventive maintenance techniques for these systems
    • Performing system checks and calibrations
    • Cleaning, cooling, and servicing requirements for Aera and Skyra systems
  • Role and Functionality of RF Coils
    • Understanding RF coils and their importance in MRI imaging
    • Different types of RF coils used in SIEMENS MRI systems
    • Common RF coil issues and how to fix them
  • RF Coil Maintenance
    • Cleaning, testing, and calibrating RF coils
    • Identifying coil artifacts and resolving them
    • Ensuring optimal image quality through RF coil maintenance
  • Cooling Systems in SIEMENS MRI Systems
    • Importance of proper cooling for superconducting magnets
    • Maintenance of cooling systems in Aera and Skyra models
    • Troubleshooting cooling system failures
  • Ventilation Systems in MRI Rooms
    • Ensuring proper airflow and temperature regulation
    • Maintaining ventilation to ensure patient and equipment safety
    • Diagnosing and addressing ventilation system issues
  • Power Supply and Electrical Components
    • Key electrical components in SIEMENS MRI systems
    • Troubleshooting power-related issues and failures
    • Maintaining power supply systems for uninterrupted MRI operations
  • Backup Power and Surge Protection
    • Importance of backup power systems for critical MRI components
    • Implementing surge protection protocols
    • Ensuring system reliability during power interruptions
  • MRI Software and Control Systems
    • Overview of the MRI control system software
    • Diagnosing software-related issues
    • Performing system diagnostics for Aera and Skyra MRI machines
  • Troubleshooting System Errors
    • Identifying and resolving common software errors
    • Understanding error logs and interpreting diagnostic results
    • Best practices for software and firmware updates
  • Creating a Preventive Maintenance Schedule
    • Designing a preventive maintenance plan for Aera and Skyra systems
    • Establishing regular check-ups and operational tests
    • Tools and resources needed for effective preventive maintenance
  • Identifying Wear and Tear
    • Recognizing early signs of component degradation
    • Conducting preemptive repairs to avoid costly downtime
    • Using performance data to anticipate system failures
  • Diagnosing Complex MRI Issues
    • Advanced troubleshooting for magnet, gradient, and RF coil systems
    • Handling malfunctioning components and performing repairs
    • Using diagnostic tools and techniques for efficient problem-solving
  • Repairing Critical Components
    • Methods for repairing key MRI parts, including the magnet and gradient coils
    • Identifying and replacing defective circuit boards, capacitors, and cables
    • Best practices for ensuring long-term performance after repairs
  • Importance of Calibration in MRI Systems
    • The role of calibration in ensuring accurate imaging
    • Procedures for calibrating Aera and Skyra systems
    • Key considerations during calibration
  • Calibration of MRI Components
    • Calibrating magnet field, gradient systems, and RF coils
    • Performing routine calibration tests
    • Addressing issues related to calibration and system accuracy
  • MRI Safety Guidelines
    • Safety measures to protect patients, staff, and equipment
    • Understanding electromagnetic field safety and its impact
    • Proper use of safety equipment when working with MRI machines
  • Compliance with Regulatory Standards
    • Ensuring the system meets local and international MRI standards
    • Keeping up-to-date with regulatory changes and safety protocols
    • Regular audits and inspections to maintain compliance
  • Planning System Upgrades
    • Recognizing when an upgrade is needed for SIEMENS MRI systems
    • Strategies for integrating new technologies without downtime
    • Compatibility considerations for hardware and software upgrades
  • Post-Upgrade Testing
    • Ensuring proper system functionality after upgrades
    • Conducting diagnostic checks and performance testing
    • Handling issues related to system integration
  • Emerging MRI Technologies
    • Role of AI and automation in modern MRI systems
    • Advancements in MRI imaging and scanning techniques
    • The future of patient care and diagnostics with MRI technology
  • Preparing for Future Maintenance Needs
    • Adapting maintenance strategies for new MRI technologies
    • Staying updated with the latest tools and techniques in MRI servicing
    • Training and certification programs for future advancements

Course Date

2025-06-09

2025-09-08

2025-12-08

2026-03-09

Course Cost

Note / Price varies according to the selected city

Members NO. : 1
£4500 / Member

Members NO. : 2 - 3
£3600 / Member

Members NO. : + 3
£2790 / Member

Related Course

Rome
Approved

The Concept of Advanced Engineering Management

2025-07-14

2025-10-13

2026-01-12

2026-04-13

£4950 £4950

$data['course']